Make immediate_commit=all the default
This commit is contained in:
@@ -56,14 +56,24 @@ Can't be smaller than the OSD data device sector.
|
||||
## immediate_commit
|
||||
|
||||
- Type: string
|
||||
- Default: false
|
||||
- Default: all
|
||||
|
||||
Another parameter which is really important for performance.
|
||||
One of "none", "all" or "small". Global value, may be overriden [at pool level](pool.en.md#immediate_commit).
|
||||
|
||||
This parameter is also really important for performance.
|
||||
|
||||
TLDR: default "all" is optimal for server-grade SSDs with supercapacitor-based
|
||||
power loss protection (nonvolatile write-through cache) and also for most HDDs.
|
||||
"none" or "small" should be only selected if you use desktop SSDs without
|
||||
capacitors or drives with slow write-back cache that can't be disabled. Check
|
||||
immediate_commit of your OSDs in [ls-osd](../usage/cli.en.md#ls-osd).
|
||||
|
||||
Detailed explanation:
|
||||
|
||||
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
||||
without cache flush. However, they are really slow (only around 1000 iops)
|
||||
if you try to fsync() each write, that is, when you want to guarantee that
|
||||
each change gets immediately persisted to the physical media.
|
||||
if you try to fsync() each write, that is, if you want to guarantee that
|
||||
each change gets actually persisted to the physical media.
|
||||
|
||||
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
||||
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
||||
@@ -75,8 +85,8 @@ really slow when used with desktop SSDs. Vitastor, however, can also
|
||||
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
||||
it explicitly.
|
||||
|
||||
This is what this parameter regulates. When it's set to "all" the whole
|
||||
Vitastor cluster commits each change to disks immediately and clients just
|
||||
This is what this parameter regulates. When it's set to "all" Vitastor
|
||||
cluster commits each change to disks immediately and clients just
|
||||
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
||||
the amount of network roundtrips performed by clients and improves
|
||||
performance. So it's always better to use server grade SSDs with
|
||||
@@ -99,9 +109,5 @@ Setting this parameter to "all" or "small" in OSD parameters requires enabling
|
||||
[disable_journal_fsync](layout-osd.en.yml#disable_journal_fsync) and
|
||||
[disable_meta_fsync](layout-osd.en.yml#disable_meta_fsync), setting it to
|
||||
"all" also requires enabling [disable_data_fsync](layout-osd.en.yml#disable_data_fsync).
|
||||
|
||||
TLDR: For optimal performance, set immediate_commit to "all" if you only use
|
||||
SSDs with supercapacitor-based power loss protection (nonvolatile
|
||||
write-through cache) for both data and journals in the whole Vitastor
|
||||
cluster. Set it to "small" if you only use such SSDs for journals. Leave
|
||||
empty if your drives have write-back cache.
|
||||
vitastor-disk tried to do that by default, first checking/disabling drive cache.
|
||||
If it can't disable drive cache, OSD get initialized with "none".
|
||||
|
||||
@@ -57,9 +57,18 @@ amplification) и эффективность распределения нагр
|
||||
## immediate_commit
|
||||
|
||||
- Тип: строка
|
||||
- Значение по умолчанию: false
|
||||
- Значение по умолчанию: all
|
||||
|
||||
Ещё один важный для производительности параметр.
|
||||
Одно из значений "none", "small" или "all". Глобальное значение, может быть
|
||||
переопределено [на уровне пула](pool.ru.md#immediate_commit).
|
||||
|
||||
Данный параметр тоже важен для производительности.
|
||||
|
||||
Вкратце: значение по умолчанию "all" оптимально для всех серверных SSD с
|
||||
суперконденсаторами и также для большинства HDD. "none" и "small" имеет смысл
|
||||
устанавливать только при использовании SSD настольного класса без
|
||||
суперконденсаторов или дисков с медленным неотключаемым кэшем записи.
|
||||
Проверьте настройку immediate_commit своих OSD в выводе команды [ls-osd](../usage/cli.ru.md#ls-osd).
|
||||
|
||||
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
|
||||
секунду) при простой случайной записи без сбросов кэша. Однако они очень
|
||||
@@ -80,7 +89,7 @@ Power Loss Protection" - одинаково быстрые и со сбросо
|
||||
эффективно утилизировать настольные SSD.
|
||||
|
||||
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
|
||||
весь кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
||||
кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
||||
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
|
||||
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
|
||||
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
|
||||
@@ -106,10 +115,3 @@ HDD-дисках с внутренним SSD или "медиа" кэшем - н
|
||||
включения [disable_journal_fsync](layout-osd.ru.yml#disable_journal_fsync) и
|
||||
[disable_meta_fsync](layout-osd.ru.yml#disable_meta_fsync), значение "all"
|
||||
также требует включения [disable_data_fsync](layout-osd.ru.yml#disable_data_fsync).
|
||||
|
||||
Итого, вкратце: для оптимальной производительности установите
|
||||
immediate_commit в значение "all", если вы используете в кластере только SSD
|
||||
с суперконденсаторами и для данных, и для журналов. Если вы используете
|
||||
такие SSD для всех журналов, но не для данных - можете установить параметр
|
||||
в "small". Если и какие-то из дисков журналов имеют волатильный кэш записи -
|
||||
оставьте параметр пустым.
|
||||
|
||||
@@ -47,14 +47,24 @@
|
||||
Не может быть меньше размера сектора дисков данных OSD.
|
||||
- name: immediate_commit
|
||||
type: string
|
||||
default: false
|
||||
default: all
|
||||
info: |
|
||||
Another parameter which is really important for performance.
|
||||
One of "none", "all" or "small". Global value, may be overriden [at pool level](pool.en.md#immediate_commit).
|
||||
|
||||
This parameter is also really important for performance.
|
||||
|
||||
TLDR: default "all" is optimal for server-grade SSDs with supercapacitor-based
|
||||
power loss protection (nonvolatile write-through cache) and also for most HDDs.
|
||||
"none" or "small" should be only selected if you use desktop SSDs without
|
||||
capacitors or drives with slow write-back cache that can't be disabled. Check
|
||||
immediate_commit of your OSDs in [ls-osd](../usage/cli.en.md#ls-osd).
|
||||
|
||||
Detailed explanation:
|
||||
|
||||
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
||||
without cache flush. However, they are really slow (only around 1000 iops)
|
||||
if you try to fsync() each write, that is, when you want to guarantee that
|
||||
each change gets immediately persisted to the physical media.
|
||||
if you try to fsync() each write, that is, if you want to guarantee that
|
||||
each change gets actually persisted to the physical media.
|
||||
|
||||
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
||||
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
||||
@@ -66,8 +76,8 @@
|
||||
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
||||
it explicitly.
|
||||
|
||||
This is what this parameter regulates. When it's set to "all" the whole
|
||||
Vitastor cluster commits each change to disks immediately and clients just
|
||||
This is what this parameter regulates. When it's set to "all" Vitastor
|
||||
cluster commits each change to disks immediately and clients just
|
||||
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
||||
the amount of network roundtrips performed by clients and improves
|
||||
performance. So it's always better to use server grade SSDs with
|
||||
@@ -90,14 +100,19 @@
|
||||
[disable_journal_fsync](layout-osd.en.yml#disable_journal_fsync) and
|
||||
[disable_meta_fsync](layout-osd.en.yml#disable_meta_fsync), setting it to
|
||||
"all" also requires enabling [disable_data_fsync](layout-osd.en.yml#disable_data_fsync).
|
||||
|
||||
TLDR: For optimal performance, set immediate_commit to "all" if you only use
|
||||
SSDs with supercapacitor-based power loss protection (nonvolatile
|
||||
write-through cache) for both data and journals in the whole Vitastor
|
||||
cluster. Set it to "small" if you only use such SSDs for journals. Leave
|
||||
empty if your drives have write-back cache.
|
||||
vitastor-disk tried to do that by default, first checking/disabling drive cache.
|
||||
If it can't disable drive cache, OSD get initialized with "none".
|
||||
info_ru: |
|
||||
Ещё один важный для производительности параметр.
|
||||
Одно из значений "none", "small" или "all". Глобальное значение, может быть
|
||||
переопределено [на уровне пула](pool.ru.md#immediate_commit).
|
||||
|
||||
Данный параметр тоже важен для производительности.
|
||||
|
||||
Вкратце: значение по умолчанию "all" оптимально для всех серверных SSD с
|
||||
суперконденсаторами и также для большинства HDD. "none" и "small" имеет смысл
|
||||
устанавливать только при использовании SSD настольного класса без
|
||||
суперконденсаторов или дисков с медленным неотключаемым кэшем записи.
|
||||
Проверьте настройку immediate_commit своих OSD в выводе команды [ls-osd](../usage/cli.ru.md#ls-osd).
|
||||
|
||||
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
|
||||
секунду) при простой случайной записи без сбросов кэша. Однако они очень
|
||||
@@ -118,7 +133,7 @@
|
||||
эффективно утилизировать настольные SSD.
|
||||
|
||||
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
|
||||
весь кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
||||
кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
||||
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
|
||||
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
|
||||
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
|
||||
@@ -144,10 +159,3 @@
|
||||
включения [disable_journal_fsync](layout-osd.ru.yml#disable_journal_fsync) и
|
||||
[disable_meta_fsync](layout-osd.ru.yml#disable_meta_fsync), значение "all"
|
||||
также требует включения [disable_data_fsync](layout-osd.ru.yml#disable_data_fsync).
|
||||
|
||||
Итого, вкратце: для оптимальной производительности установите
|
||||
immediate_commit в значение "all", если вы используете в кластере только SSD
|
||||
с суперконденсаторами и для данных, и для журналов. Если вы используете
|
||||
такие SSD для всех журналов, но не для данных - можете установить параметр
|
||||
в "small". Если и какие-то из дисков журналов имеют волатильный кэш записи -
|
||||
оставьте параметр пустым.
|
||||
|
||||
@@ -68,10 +68,6 @@ On the monitor hosts:
|
||||
but some free unpartitioned space must be available because the script creates new partitions for journals.
|
||||
- You can change OSD configuration in units or in `vitastor.conf`.
|
||||
Check [Configuration Reference](../config.en.md) for parameter descriptions.
|
||||
- If all your drives have capacitors, and even if not, but if you ran `vitastor-disk`
|
||||
without `--disable_data_fsync off` at the first step, then put the following
|
||||
setting into etcd: \
|
||||
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
|
||||
- Start all OSDs: `systemctl start vitastor.target`
|
||||
|
||||
## Create a pool
|
||||
@@ -88,6 +84,10 @@ For EC pools the configuration should look like the following:
|
||||
vitastor-cli create-pool testpool --ec 2+2 --pg_count 256
|
||||
```
|
||||
|
||||
Add `--immediate_commit none` if you added `--disable_data_fsync off` at the OSD
|
||||
initialization step, or if `vitastor-disk` complained about impossibility to
|
||||
disable drive cache.
|
||||
|
||||
After you do this, one of the monitors will configure PGs and OSDs will start them.
|
||||
|
||||
If you use HDDs you should also add `"block_size": 1048576` to pool configuration.
|
||||
|
||||
@@ -69,11 +69,6 @@
|
||||
для журналов, на SSD должно быть доступно свободное нераспределённое место.
|
||||
- Вы можете менять параметры OSD в юнитах systemd или в `vitastor.conf`. Описания параметров
|
||||
смотрите в [справке по конфигурации](../config.ru.md).
|
||||
- Если все ваши диски - серверные с конденсаторами, и даже если нет, но при этом
|
||||
вы не добавляли опцию `--disable_data_fsync off` на первом шаге, а `vitastor-disk`
|
||||
не ругался на невозможность отключения кэша дисков, пропишите следующую настройку
|
||||
в глобальную конфигурацию в etcd: \
|
||||
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`.
|
||||
- Запустите все OSD: `systemctl start vitastor.target`
|
||||
|
||||
## Создайте пул
|
||||
@@ -90,6 +85,10 @@ vitastor-cli create-pool testpool --pg_size 2 --pg_count 256
|
||||
vitastor-cli create-pool testpool --ec 2+2 --pg_count 256
|
||||
```
|
||||
|
||||
Добавьте также опцию `--immediate_commit none`, если вы добавляли `--disable_data_fsync off`
|
||||
на этапе инициализации OSD, либо если `vitastor-disk` ругался на невозможность отключения
|
||||
кэша дисков.
|
||||
|
||||
После этого один из мониторов должен сконфигурировать PG, а OSD должны запустить их.
|
||||
|
||||
Если вы используете HDD-диски, то добавьте в конфигурацию пулов опцию `"block_size": 1048576`.
|
||||
|
||||
Reference in New Issue
Block a user