# Architecture
|
|
|
|
- [Server-side components](#server-side-components)
|
|
- [Basic concepts](#basic-concepts)
|
|
- [Client-side components](#client-side-components)
|
|
- [Additional utilities](#additional-utilities)
|
|
- [Overall read/write process](#overall-read-write-process)
|
|
- [Nuances of request handling](#nuances-of-request-handling)
|
|
- [Similarities to Ceph](#similarities-to-ceph)
|
|
- [Differences from Ceph](#differences-from-ceph)
|
|
- [Implementation Principles](#implementation-principles)
|
|
|
|
## Server-side components
|
|
|
|
- **OSD** (Object Storage Daemon) is a process that directly works with the disk, stores data
|
|
and serves read/write requests. One OSD serves one disk (or one partition). OSDs talk to etcd
|
|
and to each other — they receive cluster state from etcd, and send read/write requests for
|
|
secondary copies of data to other OSDs.
|
|
- **etcd** — clustered key/value database, used as a reliable storage for configuration
|
|
and high-level cluster state. Etcd is the component that prevents splitbrain in the cluster.
|
|
Data blocks are not stored in etcd, etcd doesn't participate in data write or read path.
|
|
- **Монитор** — a separate node.js based daemon which monitors the cluster, calculates
|
|
required configuration changes and saves them to etcd, thus commanding OSDs to apply these
|
|
changes. Monitor also aggregates cluster statistics. OSD don't talk to monitor, monitor
|
|
only sends and receives data from etcd.
|
|
|
|
## Basic concepts
|
|
|
|
- **Pool** is a container for data that has equal redundancy scheme and disk placement rules.
|
|
- **PG (Placement Group)** is a "shard" of the cluster, subdivision unit that has its own
|
|
set of OSDs for data storage.
|
|
- **Failure Domain** is a group of OSDs, from the simultaneous failure of which you are
|
|
protected by Vitastor. Default failure domain is "host" (server), but you choose a
|
|
larger (for example, a rack of servers) or smaller (a single drive) failure domain
|
|
for every pool.
|
|
- **Placement Tree** (similar to Ceph CRUSH Tree) groups OSDs in a hierarchy to later
|
|
split them into Failure Domains.
|
|
|
|
## Client-side components
|
|
|
|
- **Client library** encapsulates client I/O logic. Client library connects to etcd and to all OSDs,
|
|
receives cluster state from etcd, sends read and write requests directly to all OSDs. Due
|
|
to the symmetric distributed architecture, all data blocks (each 128 KB by default) are placed
|
|
to different OSDs, but clients always know where each data block is stored and connect directly
|
|
to the right OSD.
|
|
|
|
All other client-side components are based on the client library:
|
|
|
|
- **[vitastor-cli](../usage/cli.en.md)** — command-line utility for cluster management.
|
|
Allows to view cluster state, manage pools and images, i.e. create, modify and remove
|
|
virtual disks, their snapshots and clones.
|
|
- **[QEMU driver](../usage/qemu.en.md)** — pluggable QEMU module allowing QEMU/KVM virtual
|
|
machines work with virtual Vitastor disks directly from userspace through the client library,
|
|
without the need to attach disks as kernel block devices. However, if you want to attach
|
|
disks, you can also do that with the same driver and [VDUSE](../usage/qemu.en.md#vduse).
|
|
- **[vitastor-nbd](../usage/nbd.en.md)** — utility that allows to attach Vitastor disks as
|
|
kernel block devices using NBD (Network Block Device), which works more like "BUSE"
|
|
(Block Device In Userspace). Vitastor doesn't have Linux kernel modules for the same task
|
|
(at least by now). NBD is an older, non-recommended way to attach disks — you should use
|
|
VDUSE whenever you can.
|
|
- **[CSI driver](../installation/kubernetes.en.md)** — driver for attaching Vitastor images
|
|
and VitastorFS subdirectories as Kubernetes persistent volumes. Block-based CSI uses
|
|
VDUSE (when available) or NBD — images are attached as kernel block devices and mounted
|
|
into containers. FS-based CSI uses **[vitastor-nfs](../usage/nfs.en.md)**.
|
|
- **Drivers for Proxmox, OpenStack and so on** — pluggable modules for corresponding systems,
|
|
allowing to use Vitastor as storage in them.
|
|
- **[vitastor-nfs](../usage/nfs.en.md)** — NFS 3.0 server allowing export of two file system variants:
|
|
the first is a simplified pseudo-FS for file-based access to Vitastor block images (for non-QEMU
|
|
hypervisors with NFS support), the second is **VitastorFS**, full-featured clustered POSIX FS.
|
|
Both variants support parallel access from multiple vitastor-nfs servers. In fact, you are
|
|
not required to setup separate NFS servers at all and use vitastor-nfs mount command on every
|
|
client node — it starts the NFS server and mounts the FS locally.
|
|
- **[fio driver](../usage/fio.en.md)** — pluggable module for fio disk benchmarking tool for
|
|
running performance tests on your Vitastor cluster.
|
|
- **vitastor-kv** — client for a key-value DB working over shared block volumes (usual
|
|
vitastor images). VitastorFS metadata is stored in vitastor-kv.
|
|
|
|
## Additional utilities
|
|
|
|
- **vitastor-disk** — a Vitastor OSD disk management tool. You can create, remove,
|
|
resize and move OSD partitions with it.
|
|
|
|
## Overall read/write process
|
|
|
|
- Vitastor stores virtual disks, also named "images" or "inodes".
|
|
- Each image is stored in some pool. Pool specifies storage parameters such as redundancy
|
|
scheme (replication or EC — erasure codes, i.e. error correction codes), failure domain
|
|
and restrictions on OSD selection for image data placement. See [Pool configuration](../config/pool.en.md) for details.
|
|
- Each image is split into objects/blocks of fixed size, equal to [block_size](../config/layout-cluster.en.md#block_size)
|
|
(128 KB by default), multiplied by data part count for EC or 1 for replicas. That is,
|
|
if a pool uses EC 4+2 coding scheme (4 data parts + 2 parity parts), then, with the
|
|
default block_size, images are split into 512 KB objects.
|
|
- Client read/write requests are split into parts at object boundaries.
|
|
- Each object is mapped to a PG number it belongs to, by simply taking a remainder of
|
|
division of its offset by PG count of the image's pool.
|
|
- Client reads primary OSD for all PGs from etcd. Primary OSD for each PG is assigned
|
|
by the monitor during cluster operation, along with the full PG OSD set.
|
|
- If not already connected, client connects to primary OSDs of all PGs involved in a
|
|
read/write request and sends parts of the request to them.
|
|
- If a primary OSD is unavailable, client retries connection attempts indefinitely
|
|
either until it becomes available or until the monitor assigns another OSD as primary
|
|
for that PG.
|
|
- Client also retries requests if the primary OSD replies with error code EPIPE, meaning
|
|
that the PG is inactive at this OSD at the moment - for example, when the primary OSD
|
|
is switched, or if the primary OSD itself loses connection to replicas during request
|
|
handling.
|
|
- Primary OSD determines where the parts of the object are stored. By default, all objects
|
|
are assumed to be stored at the target OSD set of a PG, but some of them may be present
|
|
at a different OSD set if they are degraded or moved, or if the data rebalancing process
|
|
is active. OSDs doesn't do any network requests, if calculates locations of all objects
|
|
during PG activation and stores it in memory.
|
|
- Primary OSD handles the request locally when it can - for example, when it's a read
|
|
from a replicated pool or when it's a read from a EC pool involving only one data part
|
|
stored on the OSD's local disk.
|
|
- When a request requires reads or writes to additional OSDs, primary OSD uses already
|
|
established connections to secondary OSDs of the PG to execute these requests. This happens
|
|
in parallel to local disk operations. All such connections are guaranteed to be already
|
|
established when the PG is active, and if any of them is dropped, PG is restarted and
|
|
all current read/write operations to it fail with EPIPE error and are retried by clients.
|
|
- After completing all secondary read/write requests, primary OSD sends the response to
|
|
the client.
|
|
|
|
### Nuances of request handling
|
|
|
|
- If a pool uses erasure codes and some of the OSDs are unavailable, primary OSDs recover
|
|
data from the remaining parts during read.
|
|
- Each object has a version number. During write, primary OSD first determines the current
|
|
version of the object. As primary OSD usually stores the object or its part itself, most
|
|
of the time version is read from the memory of the OSD itself. However, if primary OSD
|
|
doesn't contain parts of the object, it requests the version number from a secondary OSD
|
|
which has that part. Such request still doesn't involve reading from the disk though,
|
|
because object metadata, including version number, is always stored in OSD memory.
|
|
- If a pool uses erasure codes, partial writes of an object require reading other parts of
|
|
it from secondary OSDs or from the local disk of the primary OSD itself. This is called
|
|
"read-modify-write" process.
|
|
- If a pool uses erasure codes, two-phase write process is used to get rid of the Write Hole
|
|
problem: first a new version of object parts is written to all secondary OSDs without
|
|
removing the previous version, and then, after receiving successful write confirmations
|
|
from all OSDs, new version is committed and the old one is allowed to be removed.
|
|
- In a pool doesn't use immediate_commit mode, then write requests sent by clients aren't
|
|
treated as committed to physical media instantly. Clients have to send separate type of
|
|
requests (SYNC) to commit changes, and before it isn't sent, new versions of data are
|
|
allowed to be lost if some OSDs die. Thus, when immediate_commit is disabled, clients
|
|
store copies of all write requests in memory and repeat them from there when the
|
|
connection to primary OSD is lost. This in-memory copy is removed after a successful
|
|
SYNC, and to prevent excessive memory usage, clients also do an automatic SYNC
|
|
every [client_dirty_limit](../config/network.en.md#client_dirty_limit) written bytes.
|
|
|
|
## Similarities to Ceph
|
|
|
|
- Vitastor also has Pools, PGs, OSDs, Monitors, Failure Domains, Placement Tree:
|
|
- Vitastor also distributes every image data across the whole cluster.
|
|
- Vitastor is also transactional. Even though there's a "lazy fsync mode" which
|
|
doesn't implicitly flush every operation to disks, every write to the cluster is atomic.
|
|
- OSDs also have journal and metadata and they can also be put on separate drives.
|
|
- Just like in Ceph, client library attempts to recover from any cluster failure so
|
|
you can basically reboot the whole cluster and only pause, but not crash, your clients.
|
|
|
|
## Differences from Ceph
|
|
|
|
- Vitastor's primary focus is on SSDs: SSD-only and SSD+HDD clusters.
|
|
- The basic layer of Vitastor is block storage with fixed-size blocks, not object storage with
|
|
rich semantics like in Ceph (RADOS).
|
|
- PGs are ephemeral in Vitastor. This means that they aren't stored on data disks and only exist
|
|
in memory while OSDs are running.
|
|
- Vitastor OSD is (and will always be) single-threaded. If you want to dedicate more than 1 core
|
|
per drive you should run multiple OSDs each on a different partition of the drive.
|
|
Vitastor isn't CPU-hungry though (as opposed to Ceph), so 1 core is sufficient in a lot of cases.
|
|
- Metadata is always kept in memory which removes the need for extra disk reads. Metadata size
|
|
depends linearly on drive capacity and data store block size which is 128 KB by default.
|
|
With 128 KB blocks metadata takes around 512 MB per 1 TB (which is still less than Ceph wants).
|
|
Journal is also kept in memory by default, but in SSD-only clusters it's only 32 MB, and in SSD+HDD
|
|
clusters, where it's beneficial to increase it, [inmemory_journal](../config/osd.en.md#inmemory_journal) can be disabled.
|
|
- Vitastor storage layer doesn't have internal copy-on-write or redirect-write. I know that maybe
|
|
it's possible to create a good copy-on-write storage, but it's much harder and makes performance
|
|
less deterministic, so CoW isn't used in Vitastor.
|
|
- There's a "lazy fsync" mode which allows to batch writes before flushing them to the disk.
|
|
This allows to use Vitastor with desktop SSDs, but still lowers performance due to additional
|
|
network roundtrips, so use server SSDs with capacitor-based power loss protection
|
|
("Advanced Power Loss Protection") for best performance.
|
|
- Recovery process is per-object (per-block), not per-PG. Also there are no PGLOGs.
|
|
- Monitors don't store data. Cluster configuration and state is stored in etcd in simple human-readable
|
|
JSON structures. Monitors only watch cluster state and handle data movement.
|
|
Thus Vitastor's Monitor isn't a critical component of the system and is more similar to Ceph's Manager.
|
|
Vitastor's Monitor is implemented in node.js.
|
|
- PG distribution isn't based on consistent hashes. All PG mappings are stored in etcd.
|
|
Rebalancing PGs between OSDs is done by mathematical optimization - data distribution problem
|
|
is reduced to a linear programming problem and solved by lp_solve. This allows for almost
|
|
perfect (96-99% uniformity compared to Ceph's 80-90%) data distribution in most cases, ability
|
|
to map PGs by hand without breaking rebalancing logic, reduced OSD peer-to-peer communication
|
|
(on average, OSDs have fewer peers) and less data movement. It also probably has a drawback -
|
|
this method may fail in very large clusters, but up to several hundreds of OSDs it's perfectly fine.
|
|
It's also easy to add consistent hashes in the future if something proves their necessity.
|
|
- There's no separate CRUSH layer. You select pool redundancy scheme, placement root, failure domain
|
|
and so on directly in pool configuration.
|
|
|
|
## Implementation Principles
|
|
|
|
- I like architecturally simple solutions. Vitastor is and will always be designed
|
|
exactly like that.
|
|
- I also like reinventing the wheel to some extent, like writing my own HTTP client
|
|
for etcd interaction instead of using prebuilt libraries, because in this case
|
|
I'm confident about what my code does and what it doesn't do.
|
|
- I don't care about C++ "best practices" like RAII or proper inheritance or usage of
|
|
smart pointers or whatever and I don't intend to change my mind, so if you're here
|
|
looking for ideal reference C++ code, this probably isn't the right place.
|
|
- I like node.js better than any other dynamically-typed language interpreter
|
|
because it's faster than any other interpreter in the world, has neutral C-like
|
|
syntax and built-in event loop. That's why Monitor is implemented in node.js.
|
|
|
|
## Known Problems
|
|
|
|
- Deleting images in a degraded cluster may currently lead to objects reappearing
|
|
after dead OSDs come back, and in case of erasure-coded pools, they may even
|
|
reappear as incomplete. Just repeat the removal request again in this case.
|
|
This problem will be fixed in the future, along with the metadata disk storage
|
|
format update.
|